LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5CN-HR2MD-500 Communications Functions MANUAL E5CN-HR2MD-500 User's Manual
Product model: E5CN-HR2MD-500
Name: Temperature Controller
Brand: OMRON
Sort: Communications Functions User's Manual
File language: English
Terminal type: Enclosed-terminal Models.
Protective tubing length L: 20cm.
Protective tubing diameter D (mm): 6.4 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E5CN-HR2MD-500 User's Manual.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HR2MD-500 Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover) E5CN-HR2MD-500 User's Manual.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc E5CN-HR2MD-500 User's Manual. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Item: Standard models.
Connection method: PPre-wired (2 m) E5CN-HR2MD-500 Communications Functions MANUAL.
Ratings and Specifications: --.
Model: PNP output.
Simple and Affordable Fiber Amplifier Units.
Reasonable price.
Use the one-key one-function feature for quick,
easy operation.

GIGA RAY for the highest level of power in this class for,
stable detection even with sensing objects with low E5CN-HR2MD-500 Communications Functions MANUAL.
reflection or large sensing objects.
Related products