Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control E5CN-HTQQ201-FLK User's Manual
E5CN-HTQQ201-FLK
Outputs(control/transfer): 2 points: Current and Current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response E5CN-HTQQ201-FLK User's Manual.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5CN-HTQQ201-FLK User's Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Sensing method: Retro reflective.
Appearance: Horizontal.
Connection method: Pre-wired (2 m).
Sensing distance: 300 mm [100 mm].
Model: NPN output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, Ideal.
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (autoo/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-HTQQ201-FLK Communications Functions Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-HTQQ201-FLK Communications Functions Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.