Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None E5EC-PR0ASM-800 User's Manual.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485
E5EC-PR0ASM-800
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices E5EC-PR0ASM-800 User's Manual.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements E5EC-PR0ASM-800 User's Manual.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. E3Z-G62-S0SHW-E2 is selected for use with 1 optical axis and 15 axis type
Prevent mutual interference function, EN standard specifications
Groove type photoelectric sensor without optical axis adjustmentSize: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 4 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Terminal type: Enclosed-terminal Models.
Protective tubing length L: 35cm.
Protective tubing diameter D (mm): 6.4 dia.
A Wide Variety of High-precision.
Temperature SSensors E5EC-PR0ASM-800 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EC-PR0ASM-800 Manual.