LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5EC-TRX4DSM-068 RS-485 CompoWay/F Manual E5EC-TRX4DSM-068 lnstruction Manual
Product model: E5EC-TRX4DSM-068
Name: Digital Counter
Brand: OMRON
Sort: RS-485 CompoWay/F lnstruction Manual
File language: English
E3JM-R4M4T detection method: Regression reflection type with M.S.R. function,
Connection: terminal plate,
Detection range: 4m.
Output status: ON into the light; light shading ON; switch conversion type.
Output: relay. Function: timer,
2 types of cost reductionPower supply voltage: 12 to 24 VDC.
Output configuration: Complementary output E5EC-TRX4DSM-068 lnstruction Manual.
Resolution (pulses/rotation): 100, 200, 360, 500, 600; 1,000 E5EC-TRX4DSM-068
Rugged Rotary Encoder.
Incremental model.
External diameter of 60 mm.
Resolution of up to 1000 ppr.
IP65 oil-resistance with strong shaft.
Radial: 120 N, Thrust: 50 N. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1 E5EC-TRX4DSM-068 lnstruction Manual.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function E5EC-TRX4DSM-068 lnstruction Manual.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Auxiliary outputs: 1.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Moddels (Plug-in Models) with analog inputs and,
current outputs E5EC-TRX4DSM-068 RS-485 CompoWay/F Manual.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E5EC-TRX4DSM-068 RS-485 CompoWay/F Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Related products