LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5EN-HSS3BFM-500 MANUAL E5EN-HSS3BFM-500 User's Manual
Product model: E5EN-HSS3BFM-500
Name: Temperature Controller
Brand: OMRON
Sort: User's Manual
File language: English
Name: Laser Reflectors, Standard.
Ambient operating temperature range: -10 to 55°C (No icing and no condensation).
Ambient storage temperature range: -25 to 70°C (No icing and no condensation).
Ambient operating humidity range: 35 to 85% (No condensation).
Ambient storage humidity range: 35 to 85% (No condensation) E5EN-HSS3BFM-500 User's Manual. E3F3-T61 detection methods: the firing pattern,
Wire lead out type,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: 96 x 96mm E5EN-HSS3BFM-500
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5EN-HSS3BFM-500 User's Manual.
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5EN-HSS3BFM-500 User's Manual.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Appearance: Close-mounting.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON.

Complete lineup including seven different shapes E5EN-HSS3BFM-500 MANUAL.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations E5EN-HSS3BFM-500 MANUAL.
Connector with lock that mates with commercially available,
connectors.