LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5EN-HTAA2HHBFM-500 Programmable Type Manual E5EN-HTAA2HHBFM-500 User's Manual
Product model: E5EN-HTAA2HHBFM-500
Name: Temperature Controller
Brand: OMRON
Sort: Programmable Type User's Manual
File language: English
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater E5EN-HTAA2HHBFM-500 User's Manual.
Event entry point: 2.
Transfer output: - E5EN-HTAA2HHBFM-500
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E5EN-HTAA2HHBFM-500 User's Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EN-HTAA2HHBFM-500 User's Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separaately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5EN-HTAA2HHBFM-500 Programmable Type Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5EN-HTAA2HHBFM-500 Programmable Type Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
Related products
OMRON
Programmed temperature controller
E5EN-HTAA2HHBFD
OMRON Programmed temperature controller E5EN-HTAA2HHBFD
Size: 48 x 96mm. Type: power AC/DC24V wi
OMRON
Programmed temperature controller
E5EN-HTAA2HB
OMRON Programmed temperature controller E5EN-HTAA2HB
Size: 48 x 96mm. Category: power AC100
OMRON
Programmed temperature controller
E5EN-HTAA2HHBBFD
OMRON Programmed temperature controller E5EN-HTAA2HHBBFD
Size: 48 x 96mm. Type: power AC/DC24V wi