The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5EN-Q3HT-W-N User's Manual.
Event entry point: 2.
Transfer output: output (using control output)
E5EN-Q3HT-W-N
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EN-Q3HT-W-N User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Name: Laser Reflectors, Standard.
Ambient operating temperature range: -10 to 55°C (No icing and no condensation).
Ambient storage temperature range: -25 to 70°C (No icing and no condensation) E5EN-Q3HT-W-N User's Manual.
Ambient operating humidity range: 35 to 85% (No condensation).
Ambient storage humidity range: 35 to 85% (No condensation). Name: Small reflector.
Directional angle: 30° min.
Ambient operating temperature range: -25 to 55°C.
Ambient storage temperature range: -40 to 70°C.
Ambient operating humidity range: 35% to 95%.
Ambient storage humidity range: 35% to 95%.
Degree of protection: IEC IP67.
Accessories: --. Power supply voltage: AC/DC power supply selectable type.
Sensing method: Retro-reflective without MSR function.
Sensing distance: 7 m[100 mm](When using E39-R1), 11 m[100 mm](When using E39-R2).
Output configu ration: Relay.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflectivee: 2 E5EN-Q3HT-W-N MANUAL. 5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectaable power supply input (24 to 240 VDC, 24 to 240 VAC) E5EN-Q3HT-W-N MANUAL.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available.