Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 100 mm (wide view).
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models E5GN-Q03TC-FLK User's Manual.
Mechanical axis and optical axis offset of less than ±2
E5GN-Q03TC-FLK5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 1 m.
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly E5GN-Q03TC-FLK User's Manual.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Appearance: 6 E5GN-Q03TC-FLK User's Manual. 5 dia.
Sensing distance: 2 mm.
Connecting method: Pre-wired Models (2 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NC.
Wire color /pin arrangement: Brown: +V, Black: Output, Blue: 0 V.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Pulse voltage and Pulse voltage/current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communnications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5GN-Q03TC-FLK Communications Functions MANUAL. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5GN-Q03TC-FLK Communications Functions MANUAL.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.