Category: power FET MOS relay output.
Points: 16 points (1a * 16).
Public connector side treatment: NPN (corresponding to the source of public).
Rated voltage: DC24V.
Pay attention to the use of convenience and space saving,
Relay terminal for 16 point output.
The terminal block is a long and thin type with a width of 135 * Deep 40mm G9SX-EX041-T-RT USER'S MANUAL.
It can be easily connected to the common end with the independent contact and short circuit chip
G9SX-EX041-T-RT
Terminal units for power supply wiring processing can be extended.
M3.5 can be used with the Y fork type of the compression terminal (terminal width 6.2mm).
Can not use the tool to remove the relay. Relay replacement operation is simple.
Equipped with relay type and power FET MOS relay mounted type G9SX-EX041-T-RT USER'S MANUAL.
With action indication LED.
DIN guide rail installation, screw mounting common. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 40 A at 200 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series G9SX-EX041-T-RT USER'S MANUAL.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Input capacity: 16 points.
Mounted relays: NY-5W-K-IE (Fujitsu Component).
Rated load: Resistance load,
250 VAC 2 A/output, common 8 A,
30 VDC 2 A/output, common 8 A.
Rated ON current: 3 A/output.
Maximum contact voltage: 250 VAC, 125 VDC.
Maximum contact current: 3 A/output.
Maximum switching capacity: 750 VAAC, 90 WDC.
Minimum applicable load(reference value): 5 VDC 1mA.
Mechanical service life: 20,000,000 operations min.
Electrical service life: 100,000 operations min.
Number of circuits per common: 8 points/common.
Output indicators: LED display (yellow).
Isolation method: Relay isolation.
I/O power supply method: The relay drive power,
is supplied from the unit power supply.
Unit power supply current consumption:
210 mA max. (for 20.4 to 26.4-VDC power supply voltage).
Weight: 290 g max.
Expansion functions: Enabled.
Output handling for communica tions errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per oone I/O terminal unit G9SX-EX041-T-RT Manual. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software G9SX-EX041-T-RT Manual.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.