Number of elements: 2.
Insulation method: Photocoupler.
Rated supply voltage: 100 to 240 VAC.
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA G9SX-SM032-RT USER'S MANUAL.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm)
G9SX-SM032-RT
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series. Name: Short-circuit Unit.
Current flow: 10 A, 20 A.
Applicable SSR: G3PA-210B-VD, G3PA-220B-VD, G3PA-420B-VD.
Refer to Safety Precautions for All Solid State Relays.
Allows 2-wire Switching of 3-phase Power G9SX-SM032-RT USER'S MANUAL.
Ideal for 2-wire switching of 3-phase heaters.
Improve ease of operation. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models) G9SX-SM032-RT USER'S MANUAL.
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Isolation: Phototriac Coupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 20 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA SSeries G9SX-SM032-RT Manual.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Prrotective cover for greater safety G9SX-SM032-RT Manual.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)).