LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON GRT1-BT1-5 Manual GRT1-BT1-5 OPERATION MANUAL
Product model: GRT1-BT1-5
Name: CompoBus/S Module
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 3 A at 5 to 110 VDC.
Rated input voltage: 5 to 24 VDC.
International Standards for G3B Series,
Same Profile as MK Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) GRT1-BT1-5 OPERATION MANUAL.
Plug-in type, same size as MK Power Relays GRT1-BT1-5
Operation indicator provided to confirm input.
DC Output model available with 3 to 125-VDC load voltage,
range for high-voltage applications. Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 2 A at 5 to 110 VDC.
Rated input voltage: 5 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays GRT1-BT1-5 OPERATION MANUAL.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Isolation: Phototriac.
Zero cross function: No.
Indicator: No.
Rated output load: 5 A at 100 to 240 VAC GRT1-BT1-5 OPERATION MANUAL.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model.
Dedicated, compact aluminum PCB and power elements used.
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Safety outputs *3: Instantaneous, 2(semiconductor);
OFF-delayed *2: 2 (semiconductor).
Auxiliary outputs *4: 6 (semiconductor).
Logical AND connection: Inputs, 1 (semiconductor);
Outputs, 1 (semiconductor).
Max.OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
A Safety Measure for Hazardous Operations.
That Does Not Lower Productivity.
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines.
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching status,
of two safety input devices GRT1-BT1-5 Manual.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units GRT1-BT1-5 Manual.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4).
Related products
OMRON
CompoNet Communications Unit
GRT1-TS2PK
OMRON CompoNet Communications Unit GRT1-TS2PK
Name: Slice I/O Units Temperature Input
OMRON
CompoNet Communications Unit
GRT1-OD4
OMRON CompoNet Communications Unit GRT1-OD4
Name: Slice I/O Units Digital I/O Units
OMRON
CompoNet Communications Unit
GRT1-DA2V
OMRON CompoNet Communications Unit GRT1-DA2V
Name: Slice I/O Units Analog I/O Units.
OMRON
CompoNet Communications Unit
GRT1-CRT
OMRON CompoNet Communications Unit GRT1-CRT
Name: CompoNet Communication Unit. Spec