OMRON GT1-CT01 Manual GT1-CT01 SETUP MANUAL
Product model: GT1-CT01
Name: Programmable Terminals
Brand: OMRON
Sort: SETUP MANUAL
File language: English
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4) GT1-CT01 SETUP MANUAL.
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set GT1-CT01
-Two logical AND connection inputs. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output load(See note 2.): 25 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation GT1-CT01 SETUP MANUAL.
Built-in varistor effectively absorbs external surges.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.Insulation method: Phototriac.
Operation Display: Yes(green).
Output(SSR): AC.
Zero cross Function: Yes.
Rated output Load: 2 A(at 100 to 240 VAC).
Rated input voltage (socket): 12 VDC GT1-CT01 SETUP MANUAL.
Applicable model: G3RV-SR700/500-A DC12V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Name: Safety Controller.
Number of I/O: Safety inputs, 10; Test outputs, 4;
Safety outputs, Solid-state outputs: 4; Standard outputs, 4.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I/O UUnits for hard-wired diagnosis or standard signals GT1-CT01 Manual.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, vverification, standardization and reusage of,
safety control by unique programming software GT1-CT01 Manual.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified.
Related products
OMRON
Temperature Input Units
GT1-TS04T
OMRON Temperature Input Units GT1-TS04T
I/O classification: Temperature inputs.
OMRON
Digital I/O Units
GT1-ID16-1
OMRON Digital I/O Units GT1-ID16-1
Unit: Terminal lock model. I/O classif
OMRON
Digital I/O Units
GT1-OD32ML-1
OMRON Digital I/O Units GT1-OD32ML-1
Unit: High-density connector model. I/O
OMRON
Digital I/O Units
GT1-OD16ML-1
OMRON Digital I/O Units GT1-OD16ML-1
Unit: Connector model. I/O classificati