LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON GX-EC0241 Manual GX-EC0241 INSTRUCTION MANUAL
Product model: GX-EC0241
Name: Digital Temperature Controllers
Brand: OMRON
Sort: INSTRUCTION MANUAL
File language: English
Isolation: Phototriac.
Zero cross function: Yes.
Indicator: No.
Rated output load: 10 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model GX-EC0241 INSTRUCTION MANUAL.
Dedicated, compact aluminum PCB and power elements used GX-EC0241
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications GX-EC0241 INSTRUCTION MANUAL.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 60 A at 24 to 240 VAC GX-EC0241 INSTRUCTION MANUAL.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A swiitching with high,
capacity are provided in a compact body without the need of,
radiators GX-EC0241 Manual. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions GX-EC0241 Manual.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.
Related products