Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 5 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 200 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series GX-ID3218 INSTRUCTION MANUAL.
All models feature the same compact dimensions to provide a,
uniform mounting pitch
GX-ID3218
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)) GX-ID3218 INSTRUCTION MANUAL. Slim and Space-saving Power Plug-in Relay.
Reduces wiring work by 60% when combined with the,
P2RF-@-PU Push-In Plus Socket.
(according to actual OMRON measurements).
Lockable test button models available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic,
function (LED type) GX-ID3218 INSTRUCTION MANUAL.
High switching power (1-pole: 10 A). The main body: terminal type of printed circuit board.
Pole number: 4 pole.
G2A type plastic sealing type.
Because it is sealed structure, so even in the dust environment, etc..
Can also play a more stable performance than the lock type.
Parts of the relay mechanism are annealed,
Reduce the generation of internal gas.
Compared with the metal sealed relay, the price is cheaperInternal I/O common: NPN.
I/O indicators: LED display (yellow).
Unit power supply current consumption:
80 mA max. (for 20.4 to 26.4-VDC power supply voltage)
Weight: 190 g max.
Expansion functions: No.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unitt per one I/O terminal unit GX-ID3218 Manual. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software GX-ID3218 Manual.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.