Magnetic Latching Version of G2A Ideal for.
Sequence Control.
Double-winding latch system with continuous rating.
Terminals pulled from the respective junctions between the,
built-in diodes and set and reset coils allow the built-in diodes to,
be externally connected for coil surge absorption.
Excellent vibration/shock resistance with minimal secular,
decrease in latching power GX-MD1628 INSTRUCTION MANUAL
GX-MD1628
Easy monitoring of ON/OFF operation due to the built-in,
operation indicator mechanism.
Same outline dimensions as the standard models of G2A. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC, 230V.
Global standard size, low profile slim GX-MD1628 INSTRUCTION MANUAL.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location) GX-MD1628 INSTRUCTION MANUAL.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Classification: Input (bifurcated contact), SPST-NO.
Rated voltage: 12 VDC, 24 VDC, 100/110 VAC, 200/220 VAC.
Slim-styled I/O Relay Saves Space in Panel.
SPST-NO, SPST-NC, and SPDT contact forms available for,
output (SPST-NO only for input).
Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
All Output Relays provide a long endurance (1,000,000,
operations at 5 A), while all Input Relays provide microswitching,
power (100 μA at 1 V).
Approved by UL and CSA standards. Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A swiitching with high,
capacity are provided in a compact body without the need of,
radiators GX-MD1628 Manual. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions GX-MD1628 Manual.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.