Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 3 A at 4 to 48 VDC *2.
Rated input voltage: 5 to 24 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) GX-OC1601 PROGRAMMING MANUAL.
Socket type, same size as LY Power Relays
GX-OC1601
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise GX-OC1601 PROGRAMMING MANUAL.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters GX-OC1601 PROGRAMMING MANUAL.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. Type: output module.
Insulation mode: three end two-way photoelectric switch.
Action indicator: there.
Zero crossing trigger function.
Applicable load of output: AC100 2A ~ 240V.
Input rated voltage: DC24V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)A Safety Measure for Hazardous Operations.
That Does Not Lower Productivity.
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines.
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching status,
of twoo safety input devices GX-OC1601 Manual.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units GX-OC1601 Manual.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4).