Count input: No-voltage input.
Display: 7-segment LCD.
Total counter: Max. counting speed; 1 kHz.
Dedicated for use on PCB.
Total Counters and Time Counter available. Count input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD H7CX-A11 Communications Manual.
Model: Black body.
Eight-digits, counting range 0 to 99999999
H7CX-A11
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models). Type: H7CZ.
Configuration: 1-stage preset counter.
External connections: 8-pin socket.
Settings: 1-stage.
Display digits: 6 digits.
Outputs: Contact output (SPDT).
Power supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read H7CX-A11 Communications Manual.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up Key for each digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated inside the Counter.
Set value limit function prevents unexpected operation of output,
devices caused by setting mistakes.
Output counter function helps in managing the service life of the,
Counter or the load H7CX-A11 Communications Manual.
Other Features.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. Supply voltage: 24 to 240 VAC/DC.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPDT)Changed using a switch.
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7CX-A11 Manual.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input) H7CX-A11 Manual.
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.