OMRON H7CX-AWD1 Manual H7CX-AWD1 Communications Manual
Product model: H7CX-AWD1
Name: Digital Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Operating method: Incrementing, decrementing, and reversible (UP/DOWN A to F).
Mounting method: Flush mounting.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Memory backup: Yes/No (Selectable using DIP switch).
Display: Yes (8-mm high 7-segment LED) H7CX-AWD1 Communications Manual.
Models: 8 digits.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches H7CX-AWD1
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999 H7CX-AWD1 Communications Manual. 9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7CX-AWD1 Communications Manual.
External connections: 8-pin socket.
Input: Signal, Reset (NPN input).
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and inpuut circuits are isolated for safety and reliability H7CX-AWD1 Manual.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,
the load H7CX-AWD1 Manual.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.
Related products
OMRON
Multifunction Counter/Tachometer
H7CX-A4D-N
OMRON Multifunction Counter/Tachometer H7CX-A4D-N
Type: H7CX-A Series. Classification: Pr
OMRON
Multifunction Counter/Tachometer
H7CX-AWS-N
OMRON Multifunction Counter/Tachometer H7CX-AWS-N
Type: H7CX-A Series. Classification: Pr
OMRON
Multifunction Counter/Tachometer
H7CX-A-N
OMRON Multifunction Counter/Tachometer H7CX-A-N
Type: H7CX-A Series. Classification: Pr
OMRON
Multifunction Counter/Tachometer
H7CX-A4-N
OMRON Multifunction Counter/Tachometer H7CX-A4-N
Type: H7CX-A Series. Classification: Pr