Product model: H7HP-A
Name: Digital Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7HP-A Communications Manual H7HP-A
External connections: 11-pin socket.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output(SPST) H7HP-A Communications Manual.
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7HP-A Communications Manual.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Control output: Contact output: DPDT (time-limit output).
Supply voltage: 24 VDC.
11-pin models.
Solid-state Timer with Valuable Multiple-time.
Ranges and Multiple-operating Modes.
Handles a wide range of applications through eight opperating modes H7HP-A Manual.
With H3BA-N8H models, the output type can be switched.
between time-limit DPDT and time-limit SPDT + instantaneous.
SPDT using a selector.
Setting rings (order separately) to enable consistent settings.
and to limmit the setting range H7HP-A Manual.
Panel Covers (order separately) to enable various panel.
designs.
CE marking.
UL, CSA and CCC certification, conforms to LR.
Related products
OMRON
Round Water-resistant Connectors
XS2P-A422-2
OMRON Round Water-resistant Connectors XS2P-A422-2
Lock method: Front lock. Pin shape: Sol
OMRON
Round Water-resistant Connectors
XS2P-A422-1
OMRON Round Water-resistant Connectors XS2P-A422-1
Lock method: Front lock. Pin shape: DIP
OMRON
Total Counter/Time Counter
H7HP-C8
OMRON Total Counter/Time Counter H7HP-C8
Supply voltage: 100 to 240 VAC. 8-digit