Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3GN-NDC-L2-400 Communications Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out
K3GN-NDC-L2-400
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3GN-NDC-L2-400 Communications Manual. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90-95-100V (9 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common K3GN-NDC-L2-400 Communications Manual.
Rated consumption VA:7VA.
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-130V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustment shunt,
Easy to coordinate digital VR.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of the experimental switch can be easily recognized.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except). Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages and undervoltages for three-phhase,
3-wire or 4-wire power supplies K3GN-NDC-L2-400 Manual.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire,
power supply.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and,
undeervoltages K3GN-NDC-L2-400 Manual.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.