OMRON K3HB-HTA-L2AT11 Manual K3HB-HTA-L2AT11 Communications Manual
Product model: K3HB-HTA-L2AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-HTA-L2AT11 Communications Manual K3HB-HTA-L2AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied toInput type: Platinum-resistance thermometer or thermocouple K3HB-HTA-L2AT11 Communications Manual.
Supply voltage: 24 VAC/VDC.
Output: None.
Highly Visible LCD Display with 2-color (Red and Green) LEDs.
Wide input range - select from two types of platinum-resistance,
thermometers and ten types of thermocouples.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Temperature input shift and temperature unit selection functions K3HB-HTA-L2AT11 Communications Manual.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) protects against,
electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to conform to U.S. and Canadian requirements under,
the Component Recognition Program of UL.
CE marking. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically reseetting supported by one Relay K3HB-HTA-L2AT11 Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-HTA-L2AT11 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Time interval table
K3HB-PPB-L2AT11 AC100-240
OMRON Time interval table K3HB-PPB-L2AT11 AC100-240
Input type: PNP input type. Event input
OMRON
Temperature panel
K3HB-HTA-CPAC11 AC100-240
OMRON Temperature panel K3HB-HTA-CPAC11 AC100-240
Type of input: platinum resistance / the
OMRON
Temperature panel
K3HB-HTA-FLK3AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-FLK3AT11 AC/DC24
Type of input: platinum resistance / the