OMRON K3HB-VLC-B-DRT1 Manual K3HB-VLC-B-DRT1 Communications Manual
Product model: K3HB-VLC-B-DRT1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-B-DRT1 Communications Manual K3HB-VLC-B-DRT1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputPower supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control K3HB-VLC-B-DRT1 Communications Manual.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K3HB-VLC-B-DRT1 Communications Manual.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltagges K3HB-VLC-B-DRT1 Manual.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-VLC-B-DRT1 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-ET11 AC100-240
Category: external supply 100mA DC5V typ
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-CPEC11 AC/DC24
Category: external supply 100mA DC5V typ