Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V K3HB-VLC-L1BT11 Communications Manual.
Digital rotating pulse meter with high speed measurement for 50kHz
K3HB-VLC-L1BT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement.
CanOpen circuit: voltage, no voltage, DC circuit breaker.
Appearance: ADR shell.
Rated current: AC110V K3HB-VLC-L1BT11 Communications Manual.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1a, DC; closed circuit 110V 15A 1C 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms).
Relay control output for circuit breaker switching.
Quality: about 0.6kg.
External: Mount Searl N1.5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting K3HB-VLC-L1BT11 Communications Manual.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjustment, easy to coordinate.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated froom the start of operation K3HB-VLC-L1BT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-L1BT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.