Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-VLC-L1ET11 Communications Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out
K3HB-VLC-L1ET11
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-VLC-L1ET11 Communications Manual. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-VLC-L1ET11 Communications Manual.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
By 2 points can be easily setTime specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated froom the start of operation K3HB-VLC-L1ET11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-L1ET11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.