Rated primary current: 100 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported K3HB-XAA-DRT1 Communications Manual. )
Power and current can be measured simultaneously
K3HB-XAA-DRT1
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy K3HB-XAA-DRT1 Communications Manual.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications K3HB-XAA-DRT1 Communications Manual.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Wiring distance: Standard usage, Wiring cable: 50 m max. Sensing Bands: 10 m max.
Disconnection detection: Not supported.
Socket terminals: Screw Terminal Block P2RF-08/-08-E.
Reliable Sensitive Liquid Sensors,
for Stable Detection of Liquid.
Chemicals with Low Conductivity,
and Water Leakage.
New models available that are compatible with Push,
In Plus Terminal Block Sockets.
UL listed when used with Push-In Plus Terminal,
Block Sockets.
Sensor disconnection detection (K7L-AT50D@/-UD@).
Models for long-distance wiring to 400 m.
Ribbon Electrode Bands and Point Sensors available. Input type: DC voltage input type.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XAA-DRT1 Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations K3HB-XAA-DRT1 Manual.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.