OMRON K3HB-XVA-CPAC21 Manual K3HB-XVA-CPAC21 User's Manual
Product model: K3HB-XVA-CPAC21
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 24 VAC/VDC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple.
Setting unit (setting range): Unit: 10°C/°F (See note 1.).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored K3HB-XVA-CPAC21 User's Manual K3HB-XVA-CPAC21
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator. Type of input: AC voltage input.
Output type: no output K3HB-XVA-CPAC21 User's Manual.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-XVA-CPAC21 User's Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
ULSupply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 3 transistor outputs (NPN open collector);
Data transmission output, None.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated froom the start of operation K3HB-XVA-CPAC21 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVA-CPAC21 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.