OMRON K8AB-PH1 Manual K8AB-PH1 User's Manual
Product model: K8AB-PH1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K8AB-PH1 User's Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K8AB-PH1
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K8AB-PH1 User's Manual. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K8AB-PH1 User's Manual.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Detect abnormal voltages applies to equipment to,
protect against equipment failure.
Use in either overvoltage or undervoltage mode.
Monitor AC or DC currents with one Relay.
Settings for the operating valuee, hysteresis, and operating time K8AB-PH1 Manual.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crrossover wiring (all terminals) K8AB-PH1 Manual.
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability.
Related products
OMRON
Phase-sequence Phase-loss Relay
K8AB-PH Series
OMRON Phase-sequence Phase-loss Relay K8AB-PH Series
Three-phase Phase-sequence Phase-loss.
OMRON
Single-phase Voltage Relay
K8AB-VS3 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VS3 AC100/115V
Measuring voltage: 20 to 200 V AC/DC, 30
OMRON
Three-phase Voltage Relay
K8AB-PW2
OMRON Three-phase Voltage Relay K8AB-PW2
Rated input See note 2.: 3-phase 3-wir
OMRON
Temperature Monitoring Relay
K8AB-TH12S AC100-240
OMRON Temperature Monitoring Relay K8AB-TH12S AC100-240
Size: K8AB-TH 22.5 × 90 × 100 mm. Suppl