OMRON K8AC-H12CT-FLK Manual K8AC-H12CT-FLK Communications Manual
Product model: K8AC-H12CT-FLK
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Model: DGR-H (67G).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular K8AC-H12CT-FLK Communications Manual.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system K8AC-H12CT-FLK
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system K8AC-H12CT-FLK Communications Manual.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring K8AC-H12CT-FLK Communications Manual. Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Control supply voltage: 100/ 200 VAC; Without voltage fluctuation compensation.
Operating current: 0.5 to 1 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burnedd element even if one heater el,
ement among several heater elements has been burned out K8AC-H12CT-FLK Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K8AC-H12CT-FLK Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.