LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON S8EX-N01512-CN1 Manual S8EX-N01512-CN1 Connection Guide
Product model: S8EX-N01512-CN1
Name: Digital Controller
Brand: OMRON
Sort: Connection Guide
File language: English
Control power supply voltage: 100/110 VDC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) S8EX-N01512-CN1 Connection Guide.
Detect three-phase AC current for under and/or overcur,
rent using current converter S8EX-N01512-CN1
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) S8EX-N01512-CN1 Connection Guide.
LED operation indicator.
UL/CSA approval (SDV-F@). Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V S8EX-N01512-CN1 Connection Guide.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). I/O classification: Input.
Internal I/O circuit common: PNP (– common).
I/O points: 32.
I/O connection method: MIL cconnector S8EX-N01512-CN1 Manual.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 60 × 80 (W × D × H) S8EX-N01512-CN1 Manual.
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection.
Related products
OMRON
Switch Mode Power Supply
S8EX-N01505
OMRON Switch Mode Power Supply S8EX-N01505
Power ratings: 15 W. Output voltage: 5
OMRON
Switch Mode Power Supply
S8EX-N01505LC
OMRON Switch Mode Power Supply S8EX-N01505LC
Power ratings: 15 W. Output voltage: 5
OMRON
Switch Mode Power Supply
S8EX-N01548
OMRON Switch Mode Power Supply S8EX-N01548
Power ratings: 15 W. Output voltage: 48
OMRON
Switch Mode Power Supply
S8EX-N01524
OMRON Switch Mode Power Supply S8EX-N01524
Power ratings: 15 W. Output voltage: 24