LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON S8EX-N01548-CN1 Manual S8EX-N01548-CN1 EtherNet/IP Connection Guide
Product model: S8EX-N01548-CN1
Name: Digital Controller
Brand: OMRON
Sort: EtherNet/IP Connection Guide
File language: English
Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 15 W.
Output voltage: 15 V.
Output current: 1 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) S8EX-N01548-CN1 EtherNet/IP Connection Guide S8EX-N01548-CN1
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) S8EX-N01548-CN1 EtherNet/IP Connection Guide.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Input voltage: 24 VDC (24 to 28 VDC).
Output voltage(during backup operation): 22.5 V.
Output current: 2.5 A.
Prevents Equipment Stoppage, Data Loss,
and Other Problems Resulting from Momentary.
Power Failures S8EX-N01548-CN1 EtherNet/IP Connection Guide.
Provides a backup time of 500 ms at an output current of 2.5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
Parallel connections to up to four Blocks can be used to increase,
the backup time and current capacities.
Complies with SEMI F47-0200 standard.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C. Input voltage: 400 ~ 500 VAC3 phase.
Rated power: 960W.
Output voltage: 24V.
Output current: 40A.
DIN guide rail installation, with 5 A ~ 40 A output current of the power supply.
3 phase 400 ~ 500 VAC.
5, 10, 20 and 40 A; 24 VDC output.
High stability, low ripple and low noise level.
Compact design.
Add fuse protection.
Natural draft。
In addition to the CE tag, but also in compliance with UL60950 (CSA22.2-60950), UL508.
Conform to EN61000-3-2.
Parallel / series operation. Safety sensors to detect contacts by.
mounting to moving parts of hazards.
Conforms to PLe/Safety Category 3 in combination with the,
dedicated controller.
(applied when internaal relays with forcibly guided contacts,
disable hazard source directly) S8EX-N01548-CN1 Manual.
Simple one-unit structure integrating sensor and cover.
Resistant to the side force.
Can be used in various applications.
Sensor length: 150 mm too 6,100 mm, Height: 34 mm to 80 mm S8EX-N01548-CN1 Manual.
Models with sealing covers for doors are provided(SGE-245L).
Certified standard: EN1760-2 (Safety Edge Standard).
Related products
OMRON
Switch Mode Power Supply
S8EX-N01512L
OMRON Switch Mode Power Supply S8EX-N01512L
Power ratings: 15 W. Output voltage: 12
OMRON
Switch Mode Power Supply
S8EX-N03015L
OMRON Switch Mode Power Supply S8EX-N03015L
Power ratings: 30 W. Output voltage: 15
OMRON
Switch Mode Power Supply
S8EX-N03048LC
OMRON Switch Mode Power Supply S8EX-N03048LC
Power ratings: 30 W. Output voltage: 48
OMRON
Switch Mode Power Supply
S8EX-N01515
OMRON Switch Mode Power Supply S8EX-N01515
Power ratings: 15 W. Output voltage: 15