LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON S8JX-P60024CD Manual S8JX-P60024CD EtherNet/IP Connection Guide
Product model: S8JX-P60024CD
Name: Digital Controller
Brand: OMRON
Sort: EtherNet/IP Connection Guide
File language: English
Input voltage: 400 ~ 500 VAC3 phase.
Rated power: 240W.
Output voltage: 24V.
Output current: 10A.
DIN guide rail installation, with 5 A ~ 40 A output current of the power supply.
3 phase 400 ~ 500 VAC.
5, 10, 20 and 40 A; 24 VDC output.
High stability, low ripple and low noise level.
Compact design.
Add fuse protection S8JX-P60024CD EtherNet/IP Connection Guide.
Natural draft。
In addition to the CE tag, but also in compliance with UL60950 (CSA22 S8JX-P60024CD2-60950), UL508.
Conform to EN61000-3-2.
Parallel / series operation. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block) S8JX-P60024CD EtherNet/IP Connection Guide.
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22 S8JX-P60024CD EtherNet/IP Connection Guide. 2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Control power supply voltage: 24 VDC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Availabble in 7 supply voltage configurations S8JX-P60024CD Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8JX-P60024CD Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Switching Mode Power Supply
S8JC-ZS10024CD-AC2
OMRON Switching Mode Power Supply S8JC-ZS10024CD-AC2
Type: S8JC-ZS series models list. Meet t
OMRON
Switch Mode Power Supply
S8JX-G30024CD
OMRON Switch Mode Power Supply S8JX-G30024CD
Configuration: Covered Power Supplies.
OMRON
Switch Mode Power Supply
S8JX-G10024CD
OMRON Switch Mode Power Supply S8JX-G10024CD
Configuration: Covered Power Supplies.
OMRON
Switching Mode Power Supply
S8VM-10024CD
OMRON Switching Mode Power Supply S8VM-10024CD
Category: incidental cover type. Structu