OMRON S8VS-09024S Manual S8VS-09024S Installation and Operating Manual
Product model: S8VS-09024S
Name: Code Reader
Brand: OMRON
Sort: Installation and Operating Manual
File language: English
Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication S8VS-09024S Installation and Operating Manual.
Monitor and Simple Functions for.
Easy System Commissioning S8VS-09024S
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) S8VS-09024S Installation and Operating Manual.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Control voltage: 200/220/240 VAC.
Reset: Automatic.
Model: Instantaneous type (See note 1.).
Solid-state Relay Provides Three Operating.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase S8VS-09024S Installation and Operating Manual.
LEDs indicate operation of the selected operating function.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s.
Protects the motor from reversing without starting it.
before using the K2CM. Appearance: insert type.
Control supply voltage: DC48V.
Action elements: overload detection.
Action characteristic: anti time limit action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock time,, instantaneous action, etc S8VS-09024S Manual. , are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT orr the relay part is not needed, and the use is simple S8VS-09024S Manual.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple.
Related products
OMRON
Switch Mode Power Supply
S8VS-09024AS
OMRON Switch Mode Power Supply S8VS-09024AS
Power ratings: 90 W. Input voltage: 100
OMRON
Switch Mode Power Supply
S8VS-03024
OMRON Switch Mode Power Supply S8VS-03024
Power ratings: 30 W. Input voltage: 100
OMRON
Switch Mode Power Supply
S8VS-09024BES
OMRON Switch Mode Power Supply S8VS-09024BES
Power ratings: 90 W. Input voltage: 100
OMRON
Switch Mode Power Supply
S8VS-09024S
OMRON Switch Mode Power Supply S8VS-09024S
Power ratings: 90 W. Input voltage: 100