OMRON SE-K4TN Manual SE-K4TN User's Manual
Product model: SE-K4TN
Name: SWITCHINGPOWER SUPPLY
Brand: OMRON
Sort: User's Manual
File language: English
Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 48 VDC.
Overcurrent detection: Inverse type.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available SE-K4TN User's Manual.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring SE-K4TN
DIN sized (48 mm x 96 mm). Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block) SE-K4TN User's Manual.
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107 SE-K4TN User's Manual. 1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) I/O classification: Digital output.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method: M3 terminal block.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wire terminals each,
connecting to a single wire.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction SE-K4TN Manual. Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch SE-K4TN Manual.
Related products
OMRON
Motor Protective Relay
SE-KP1AN
OMRON Motor Protective Relay SE-KP1AN
Control voltage: 100/110/120 VAC. Reset
OMRON
Motor Protective Relay
SE-KQ1N
OMRON Motor Protective Relay SE-KQ1N
Control voltage: 100/110/120 VAC. Reset
OMRON
Phase-sequence Phase-loss Relay
K8DS-PH1
OMRON Phase-sequence Phase-loss Relay K8DS-PH1
Function: Phase sequence and phase loss