Name: Heat/Cool Temperature Control Module.
Model: C200H-TV002.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Voltage output(transistor output used for cooling outputs).Type: Analog inputs, counter inputs, analog outputs.
12 DC inputs: Yes.
Counter inputs: 1.
Analog inputs: 1 CP1W-TS101 I/O Wiring Diagram.
8 transistor outputs: Yes.
2 pulse outputs: No.
2 analog outputs: Yes
CP1W-TS101Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (PNP) output, 2 loops.UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points CP1W-TS101 I/O Wiring Diagram.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.One Ethernet Option Board can be mounted in either option board slot 1 or 2.
Note: Cannot be used for the CP1L-L10.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs CP1W-TS101 I/O Wiring Diagram.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CP1W-TS101 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1W-TS101 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.