C500-OA I/O Unit Triac Output 16 pts C500-OA226.
AC250V 1.2A.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV CPM1A-10CDR-A-V1 I/O Wiring Diagram.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block
CPM1A-10CDR-A-V1
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CPM1A-10CDR-A-V1 I/O Wiring Diagram.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CPM1A-10CDR-A-V1 I/O Wiring Diagram.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Power supply: AC power supply.
Output method: Relay output.
Inputs points: 24 points.
Outputs points: 16 points.C200H A Backplane I/O Mounting Bracket For 8 Slots C200H-ATT83.Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CPM1A-10CDR-A-V1 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM1A-10CDR-A-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.