Operation indicator: Without operating indication; Standard load.
Ratings: 5 A at 250 VAC; 4 A at 30 VDC.
Actuator: Roller lever (high sensitivity model).
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4N-4262 INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection
D4N-4262
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4N-4262 INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Ratings: 1 A at 125 VAC.
LED indicator: Without indicator.
Actuator: Crossroller plunger D4N-4262 INSTRUCTION sheet.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Ratings: 0.1 A at 125 VAC.
Cable: VCTF oil-resistant cable*.
Actuator: Plastic rod.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Caable lengths of 3 and 5 m available on standard models D4N-4262 Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-4262 Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)