LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4N-4272 Manual D4N-4272 INSTRUCTION sheet
Product model: D4N-4272
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: 1 A at 125 VAC.
LED indicator: Without indicator.
Actuator: Crossroller plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement D4N-4272 INSTRUCTION sheet.
Triple-seal construction to provide IEC IP67 degree of protection D4N-4272
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Specifications: Input, PNP (- common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector D4N-4272 INSTRUCTION sheet.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities D4N-4272 INSTRUCTION sheet.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inssertion point D4N-4272 Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-4272 Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-4B31
OMRON Safety Limit Switch D4N-4B31
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-8222
OMRON Safety Limit Switch D4N-8222
Actuator: Roller lever resin lever, res
OMRON
Pull-reset Safety Limit Switch
D4N-4B2GR
OMRON Pull-reset Safety Limit Switch D4N-4B2GR
Actuator: Adjustale roller lever, form
OMRON
Pull-reset Safety Limit Switch
D4N-8B72R
OMRON Pull-reset Safety Limit Switch D4N-8B72R
Actuator: One-way roller arm lever vert