OMRON E2E-C06S02-CJ-C2 Manual E2E-C06S02-CJ-C2 INSTRUCTION sheet
Product model: E2E-C06S02-CJ-C2
Name: proximity sensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2E-C06S02-CJ-C2 INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers E2E-C06S02-CJ-C2
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Specification: Resin, standard type.
Shaft interior (tolerance *) exterior dia: 4 dia. (Height: 8), 13 dia E2E-C06S02-CJ-C2 INSTRUCTION sheet.
Couplings.
Coupling Materials and Characteristics.
OMRON provides two types of couplings for different.
application conditions: Resin and metal.
Select the best type for the application. Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models E2E-C06S02-CJ-C2 INSTRUCTION sheet. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furthher performance improvement E2E-C06S02-CJ-C2 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E2E-C06S02-CJ-C2 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.