LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E3S-AT71-M1J Manual E3S-AT71-M1J INSTRUCTION sheet
Product model: E3S-AT71-M1J
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input E3S-AT71-M1J INSTRUCTION sheet.
Heating wire break, SSR fault detection function: 1 points E3S-AT71-M1J
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm E3S-AT71-M1J INSTRUCTION sheet.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E3S-AT71-M1J INSTRUCTION sheet.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: M12 (Brass); Single; Shielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3S-AT71-M1J Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3S-AT71-M1J Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT91
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT91
Sensing method: Through-eam Sensors. A
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT81
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT81
Sensing method: Through-eam Sensors. A
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT21
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT21
Sensing method: Through-eam Sensors. A
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT36
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT36
Sensing method: Through-eam Sensors. A