OMRON G3J-T211BL Manual G3J-T211BL INSTRUCTION MANUAL
Product model: G3J-T211BL
Name: solid-state contactor
Brand: OMRON
Sort: INSTRUCTION MANUAL
File language: English
Terminal (Wire connection): Screw terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 48V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel G3J-T211BL INSTRUCTION MANUAL.
Realized opening and closing ability with one pole 6 A slim shape G3J-T211BL
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs G3J-T211BL INSTRUCTION MANUAL.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Contact configuration: Four SPST-NO relays.
Heat sink: No.
Built-in SSRs: G3SD-Z01P-PD.
Zero cross function: No.
Applicable output load: 0.6 A at 3 to 26 VDC(See note 2.).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit G3J-T211BL INSTRUCTION MANUAL.
Easy wiring with separate I/O terminal construction.
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws. Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 .
Rated input voltage: 12 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Socket type, same size as LY Power Relays.
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA usiing Au-plated G3J-T211BL Manual.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed locatiion) G3J-T211BL Manual.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging.
Related products