LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON G3PF-525B-STB Manual G3PF-525B-STB INSTRUCTION MANUAL
Product model: G3PF-525B-STB
Name: Solid State Relay
Brand: OMRON
Sort: INSTRUCTION MANUAL
File language: English
Terminals: Push-In Plus terminal blocks.
Type: Output *2.
Points: 16.
Internal I/O circuit common: NPN (+ common).
Rated voltage: 24 VDC.
I/O Relay Terminals with 16 Points and,
Push-In Plus terminal blocks to,
Downsize Control Panels and Save Labor.
I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays G3PF-525B-STB INSTRUCTION MANUAL.
Push-In Plus terminal blocks are used to save wiring work in,
comparison with traditional screw terminals G3PF-525B-STB (Wiring time is,
reduced by 60%* in comparison with traditional screw terminals.).
Work is reduced ever further with one-step cable connection to the PLC.
Diode provided for coil surge absorption.
Operation indicators for immediate recognition of I/O signal status G3PF-525B-STB INSTRUCTION MANUAL.
Accepts G3RV Slim I/O SSRs.
DIN Track or screw mounting. Applicable I/O Relay Terminal: G70V-SID16P-1.
Type: Input.
Internal I/O circuit common: PNP (+ common).
Rated voltage: 24 VDC.
I/O Relay Terminals with 16 Points and,
Push-In Plus terminal blocks to,
Downsize Control Panels and Save Labor.
I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays.
Push-In Plus terminal blocks are used to save wiring work in,
comparison with traditional screw terminals G3PF-525B-STB INSTRUCTION MANUAL. (Wiring time is,
reduced by 60%* in comparison with traditional screw terminals.).
Work is reduced ever further with one-step cable connection to the PLC.
Diode provided for coil surge absorption.
Operation indicators for immediate recognition of I/O signal status.
Accepts G3RV Slim I/O SSRs.
DIN Track or screw mounting. Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.

RS-485 communications to set manipulated variables and,
monitor load current G3PF-525B-STB Manual.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3PF-525B-STB Manual.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.