SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
Type: DC-switching.
Contact form: DPDT+DPST-NO.
Cased: Plug-in (octal pins) terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil) OMRON G3PF-535B.
Operational response fast enough to enable pulse signal power applications
G3PF-535B
Ambient operating temperature: –10°C to 55°C. Contact configuration: Four SPST-NO relays.
Heat sink: Yes.
Built-in SSRs: G3SD-Z01P-PD.
Zero cross function: No.
Applicable output load: 1 A at 3 to 26 VDC (See note 2.).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit OMRON G3PF-535B.
Easy wiring with separate I/O terminal construction.
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws. Standard certification: No.
Action indicator: No.
Applicable load of output: DC4 3A ~ 48V.
Input rated voltage: DC4 ~ 24V.
Insulation: photo coupler OMRON G3PF-535B.
Zero trigger function: No.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineeup also includes models that are compliant,
with the LR and VDE safety standards G3PF-535B.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) G3PF-535B.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).