OMRON GT1-ID16-1 Manual GT1-ID16-1 Safety Precautions
Product model: GT1-ID16-1
Name: TEMPERATURE INPUT UNIT
Brand: OMRON
Sort: Safety Precautions
File language: English
Type: output module.
Insulation mode: three end two-way photoelectric switch.
Action indicator: there.
Zero crossing trigger function.
Applicable load of output: AC100 2A ~ 240V.
Input rated voltage: DC24V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete GT1-ID16-1 Safety Precautions.
Can be used for I/O type P7TF terminal GT1-ID16-1 Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Standard certification: No.
Insulation: photo coupler.
Zero trigger function: No GT1-ID16-1 Safety Precautions.
Action indicator: No.
Applicable load of output: DC4 3A ~ 48V.
Input rated voltage: DC4 ~ 24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input GT1-ID16-1 Safety Precautions. (type N)Cable with connector (1 to 1) /G79-_C.
L size: 5000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms. (Default setting: 1 ms)
Number of circuits per common: 8 points/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Input device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple conntacts GT1-ID16-1 Manual.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,

switch and with tool software GT1-ID16-1 Manual.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.
Related products
OMRON
Expansion Units
XWT-OD16-1
OMRON Expansion Units XWT-OD16-1
Name: Expansion Units. Specifications:
OMRON
Digital I/O Units
GT1-ID16ML-1
OMRON Digital I/O Units GT1-ID16ML-1
Unit: Connector model. I/O classificati
OMRON
Digital I/O Units
GT1-ID32ML-1
OMRON Digital I/O Units GT1-ID32ML-1
Unit: High-density connector model. I/O
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-MD16-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-MD16-1
Name: Two-tier Screw Terminal Block. Sp