Name: Two-tier Screw Terminal Block.
8 inputs/8 outputs; PNP.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Unit: Connector model.
I/O classification: Digital input.
Internal I/O common: NPN (+ common).
I/O points: 16.
I/O connections: Fujitsu connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available OMRON CRT1-MD16-1.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires
CRT1-MD16-1
DIN track mounting. I/O classification: Output.
Internal I/O circuit common: PNP (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection) OMRON CRT1-MD16-1.
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Specifications: Inputs, PNP (- common), 32 inputs OMRON CRT1-MD16-1.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws. Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansioon unit per one I/O terminal unit CRT1-MD16-1. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software CRT1-MD16-1.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.