Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CJ1W-DA021 PDF datasheet.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CJ1W-DA021
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Short protection for 10-pin terminal block (package of 10 covers) CJ1W-DA021 PDF datasheet. 12 pts.Product name: E@@S type CPU Units with 20 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 12; Outputs, 8;
Output type, Relay; Program capacity, 2K steps; memory Data capacity, 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.17A; 24 V,0.08A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient CJ1W-DA021 PDF datasheet.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. UM: 63.2K words.
DM: 6K words.
EM: 6Kx16 banks(96K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.I/O Cable (for I/O to Interface Racks) 2 m (L) CV500-CN222Model: C200H-MR833.
Description: RAM, 8K words, battery back-up.with clock(CPU21, CPU23 only).SPACER FOR II101 C500-SP001Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open ccollector,
NPN outputs (pulses) CJ1W-DA021 datasheet PDF catalog.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output CJ1W-DA021 datasheet PDF catalog.