CV500-BS CPU Bus Unit BASIC Unit CV500-BSC61.
RS-232C: 1 port.
GP-IB: 1 port.
(w/EEPROM).C500-NC Special I/O Unit Position Control For pulse motors 1 axis C500-NC113.Product name: CS1 CPU Backplane.
Specifications: For both CS/C200H-series Units,
2 slots(Note:Expansion Racks,
cannot be connected) CS1W-BC033 PDF datasheet.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes
CS1W-BC033
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CS1W-BC033 PDF datasheet. Number of outputs: 8 pts.
Input Voltage: 250 VAC, 24 VAC.
Max Switching Current: 2 Amps.
Common Type: Independent.C500-IA I/O Unit AC Input 32 pts C500-IA223(3G2A5-IA223).
AC200-240V 10mA.C500-ID Special I/O Unit ID Sensor Unit General Purpose C500-IDS21.C500-OA I/O Unit Triac Output 24 pts C500-OA223(3G2A5-OA223) CS1W-BC033 PDF datasheet.
AC250V 1A.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CS1W-BC033 datasheet PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-BC033 datasheet PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.