OMRON K3HB-PNB-ABCD1 AC100-240 datasheet PDF catalog K3HB-PNB-ABCD1 AC100-240 PDF datasheet
Product model: K3HB-PNB-ABCD1 AC100-240
Name: Time interval table
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-PNB-ABCD1 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable fromSupply voltage: 24 VDC K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs (SPST-NO) Normally energized relays (See note.);
Data transmission output, DC voltage (0 to 5 V, 1 to 5 V, 0 to 10 V).
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operatioon K3HB-PNB-ABCD1 AC100-240 datasheet PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PNB-ABCD1 AC100-240 datasheet PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.