LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON K3HB-PPB-ABCD1 AC100-240 datasheet PDF catalog K3HB-PPB-ABCD1 AC100-240 PDF datasheet
Product model: K3HB-PPB-ABCD1 AC100-240
Name: Time interval table
Brand: OMRON
Sort: PDF datasheet
File language: English
Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages K3HB-PPB-ABCD1 AC100-240 PDF datasheet.
Manual resetting and automatically resetting supported by one Relay K3HB-PPB-ABCD1 AC100-240
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Inverse type K3HB-PPB-ABCD1 AC100-240 PDF datasheet.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-PPB-ABCD1 AC100-240 PDF datasheet.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse.
Measuring, increasing or deecreasing pulse meter K3HB-PPB-ABCD1 AC100-240 datasheet PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulattive pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulse is 30kHz K3HB-PPB-ABCD1 AC100-240 datasheet PDF catalog.
Support for no voltage contact input can be up to 3
Related products
OMRON
Time interval table
K3HB-PPB-ABCD1 AC100-240
OMRON Time interval table K3HB-PPB-ABCD1 AC100-240
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PNB-ABCD1 AC100-240
OMRON Time interval table K3HB-PNB-ABCD1 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PPB-ABCD1 AC/DC24V
OMRON Time interval table K3HB-PPB-ABCD1 AC/DC24V
Input type: PNP input type. Event input