OMRON K3HB-PNB-L2AT11 AC/DC24V datasheet PDF catalog K3HB-PNB-L2AT11 AC/DC24V PDF datasheet
Product model: K3HB-PNB-L2AT11 AC/DC24V
Name: Time interval table
Brand: OMRON
Sort: PDF datasheet
File language: English
Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately K3HB-PNB-L2AT11 AC/DC24V PDF datasheet.
One SPDT output relay, 6 A at 250 VAC (resistive load) K3HB-PNB-L2AT11 AC/DC24V
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control K3HB-PNB-L2AT11 AC/DC24V PDF datasheet.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K3HB-PNB-L2AT11 AC/DC24V PDF datasheet.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic contrrol K3HB-PNB-L2AT11 AC/DC24V datasheet PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-PNB-L2AT11 AC/DC24V datasheet PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Rotating pulse meter
K3HB-RNB-AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ
OMRON
Rotating pulse meter
K3HB-RPB-FLK3AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RPB-FLK3AT11 AC/DC24V
Input type: PNP input type. Event input
OMRON
Rotating pulse meter
K3HB-RPB-FLK1AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RPB-FLK1AT11 AC/DC24V
Input type: PNP input type. Event input