Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-R Series PDF datasheet.
High speed sampling of 50 /s (20ms)
K3HB-R Series
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
Type DeviceNet seriesModels: UVR+OVR.
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched K3HB-R Series PDF datasheet.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system K3HB-R Series PDF datasheet.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring. Ideal to prevent heater overheating.
Self-latching output to contribute to safe,
equipment operation.
Set the temperature with ultra-simple rotary switches.
Digitally set the temperature to between 0 and 999°C in 1°C increments with one,
Relay (K8DT-TH1@@).
(K8DT-TH2@@: Set to between 0 and 1,800°C in 10°C increments.).
Connect a thermocouple or platinum resistancce thermometer K3HB-R Series datasheet PDF catalog.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crrossover wiring (all terminals) K3HB-R Series datasheet PDF catalog.
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability.